Revealing an Underlying Mechanism of Overuse Injuries

A study involving electromyography and handgrip dynamometry, enabled by Trigno Link
Watch the Full Playlist

Introduction 

Almost 30% of all musculoskeletal injuries occur at the wrist, accounting to nearly 14 million injuries each year. The 2nd most common injury to the wrist is Carpal Tunnel Syndrome, an overuse injury that impacts 1 in 20 people around the globe.

Identifying the critical factors that cause overuse injuries like Carpal Tunnel Syndrome demands the synchronization of electromyography and handgrip force as a means of evaluating any impairment in neural signaling that affects the wrist. This integration process has been historically tedious.

Trigno Link is an intuitive integration system that solves this problem by providing a synchronous pathway for researchers to explore the relationship between electromyography and physiological data from the human body.

Below, we have outlined an experiment utilizing the Link’s integration pathway to highlight a possible mechanism of overuse injuries, in addition to a potential direction for injury prevention.

Background

Jamar is trusted by physical therapists and certified hand therapists as a reliable and accurate tool for the evaluation of handgrip strength.

  • Easy to use and provides a variety of width options to accommodate different hand sizes.
  • Reports hand-grip force in pounds or kilograms and can be used to assess maximal voluntary contraction.

  • Maximal handgrip strength can be a strong indicator of mortality, mobility, and bone health.

EMG is an experimental technique, typically used within human movement assessments and performance monitoring, that involves the recording and analysis of the electrical signals that emanate from the muscles during contractions and force production. By gaining insight into the status of muscular excitation, researchers, clinicians, sports practitioners, and engineers have been able to determine:

  • The level of muscular effort involved – gained from assessing the overall EMG signal amplitude.

  • Coordination between muscles – assessed by the activation timings of muscles.

  • The effects of muscle fatigue – an exploration of the frequency component of the EMG signal.

  • Neural control strategies – how the brain is adapting to training or external stimuli

With the help of Link, Trigno EMG is now the only system capable of integrating physiological and EMG data.

Benefits of integrating EMG with hand dynamometry include:

Muscle force decreases as a product of fatigue. Alongside EMG data, this can provide a strong picture of the physiological responses to a fatiguing task.

Actual force feedback from the Jamar can be compared to electrical signals picked up by EMG sensors to allow a contrast between muscle force production and neural signaling within the body.

Comparing the neural and mechanical components of force production provides researchers and clinicians with a valuable tool for rehabilitation.

Combining EMG with force production can help establish the mind-muscle connection, which can be improved through intentional training.

Check out a small study we conducted to demonstrate the interaction between EMG and Jamar!

Experiment Equipment

Equipment Type Equipment Name
Software Trigno Discover 1.6.4
Software EMGworks® Analysis 4.0
System Trigno Research + Base Station
Hardware Trigno Link
Sensor Trigno Quattro EMG Sensor
Biofeedback Device Jamar Hand Dynamometer
Biofeedback Device Moxy Muscle Oxygenation Sensor
Biofeedback Device Polar Heart Rate Monitor

Experiment Protocol

Our protocol was designed to monitor forearm flexor and extensor muscle activity during a sustained submaximal grasping task by using a Jamar dynamometer that presented force feedback with a slight delay to magnify cognitive load. Here was our testing procedure.

  • The participant wore a Polar Heart Rate monitor.

  • One Trigno Quattro EMG sensor was placed on the skin with heads on the Flexor Carpi Radialis (FCR), Flexor Digitorum Superficialis (FDS), Extensor Carpi Radialis (ECR), and Extensor Digitorum (ED).
  • One Moxy Sensor was placed on the extensor compartment muscles.
  • The participant sat on a chair with their forearm resting on a table and their wrist hanging over the edge of the table. The Jamar Hand dynamometer was adjusted to fit the width of the subject’s hand.

  • The participant gripped the Jamar Hand dynamometer with their dominant hand and performed a 10-second maximal contraction. The peak value was recorded as the subject’s maximal voluntary contraction (MVC).
  • The participant performed a fatiguing task where they held a submaximal contraction at 50% of their MVC. The task ended when the subject could no longer maintain the 50% value.
  • The participant rested for 1 hour and then repeated the above steps while wearing a wrist brace designed for people with carpal tunnel syndrome.

Acquisition and Analysis

EMG and biofeedback data were recorded using Trigno Discover 1.6.4.

Following collection, data were processed using EMGworks® Analysis to compute the change in EMG median frequency, a commonly used indicator of localized fatigue representing the accumulation of muscle metabolites that impede force development. A drop in median frequency indicates greater localized fatigue.

Results and Discussion

What are the differences in fatigability for the different forearm muscles?

Figure 1: Comparing muscle fatigability for extensor and flexor compartment muscles

Figure 1 shows the raw median frequency and force signals (left) and calculated changes in median frequency (right) for flexor (blue/orange) and extensor (grey/gold) muscles during the No Brace trial. Note that the change in median frequency shown in the extensors is much larger than the change shown in the flexors. This finding suggests that the extensors show more localized fatigue than the primary movers, the flexors. This finding may help explain why the extensors are more susceptible to overuse injuries.

How does the brace influence fatigue in the extensor compartment muscles?

Figure 2: The effects of wearing a brace on fatigue in the extensor compartment muscles

Figure 2 shows the raw median frequency and force signals (left) and calculated changes in median frequency (right) for the No Brace trial (grey/gold) and the Brace trial (blue/green). The extensor digitorum (ED) showed a 65.3Hz decrease when wearing a brace compared to a 76.6Hz decrease when not wearing a brace, and the extensor carpi radialis (ECR) showed a 61.5Hz decrease when wearing a brace compared to a 99.9Hz decrease when not wearing a brace. This indicates that wearing a brace is associated with less localized fatigue in the extensor compartment muscles.

How do the other physiological variables respond?

Figure 3: Other indicators of fatigue

Figure 3 shows the raw median frequency, heart rate, muscle oxygenation (SmO2), and force signals (left) and calculated changes in heart rate and SmO2 (right). This figure shows that there are many possible fatigue indices that can be measured concurrently, such as an increase in heart rate and a decrease in muscle oxygenation (SmO2). An inverse relationship between heart rate and muscle oxygenation is expected, as our bodies try to replenish the oxygen which has been depleted by the fatigue task.

Expanding with Link

As indicated by the data above, introducing a cognitive component to a normal fatiguing task reveals that antagonistic extensor muscles fatigue more than agonistic flexor muscles. This presents a possible causal mechanism for the overuse injuries in the finger and wrist extensors. Our data show that wearing wrist brace can decrease fatigue and therefore might attenuate some risk. Researchers or clinicians interested in investigating overuse injuries like carpal tunnel syndrome should use Trigno Link to explore the effectiveness of different prevention strategies, such as bracing or taping.

Good research creates interesting questions. Even after this simple experiment, there are questions related to the factors of fatigue that present themselves. For example, why does muscle oxygenation climb after dropping off in the middle of the trial? Is this related to the steady increase in (systemic) heart rate? How does this compare to more localized (SmO2) indicators of fatigue?

These comparisons can be drawn together easily by using Trigno Link.

References

FAQs

Jamar connects digitally to the Link which allows Trigno Discover to present force values in kilograms or pounds. Values are presented numerically and updated every second.

Yes, the Trigno Link is designed to integrate third-party biofeedback data with EMG. Therefore, the Link cannot be used without pairing a Trigno EMG sensor.

Currently, the Trigno Link can only be utulized within our Trigno Discover software. However, additional metrics can be brought into Trigno Discover via the use of our analog adapter or trigger module.

The Link can only connect to either Bluetooth or ANT+ at any given time. Refer to the following table for a full wireless connection compatibility guide to all our third-party devices:

ANT+ Bluetooth
Polar Heart Rate Polar Heart Rate
Moxy NIRS Sensor Moxy NIRS Sensor
Wahoo Cadence Sensor Wahoo Cadence Sensor
Wahoo Bike Ergometer VO2 Master
Jamar Hand Dynamometer

Our team is constantly looking for high-quality, useful biofeedback tools that can be integrated via the Trigno Link. We are open to expanding to new devices! Do you have any products you want to see integrated with Trigno Link? Let us know!