Baseline Level
The Baseline Level acts as the multiplier against the smallest RMS value from the random windows.
Window Length
Window length of the random windows used to calculate the baseline.
Number of Windows
The number of random windows to be used to calculate the baseline.
Suppress Spikes and Gaps
If selected, short on or off periods are removed from the threshold output before the rate output is calculated.
Suppression Time
The minimum allowable duration of an active or inactive interval when spikes and gaps are suppressed.
Rectify Input
If selected the input data is rectified.
Low Pass Filter Input
If selected the input data is low-pass filtered prior to applying the threshold cutoff but after rectification (if selected).
LPF Cutoff Frequency
If the low pass option is selected, this is the cutoff frequency used for the low pass filter.
Interpolation Type
To have the rate data displayed using Piecewise Constant, Piecewise Linear, or Cosine Smoothing interpolation methods.
Data Sampling Frequency
The sampling frequency of the output.